  • Unibräu: Electrical Requirements

    Unibräu 10G 120V option

    • 3 wire 120V power input 
    • Nema 5-15 outlet (standard 120V receptacle) 

                   

    • requires standard household 15A breaker in the electrical panel
    • comes with our 120V 1650W brewing element
    • 2m (6') power cord included from outlet to SV1 controller

    *GFCI receptacle is recommended for added protection.  These are standard in most North American kitchens.

    *Electrical installations should be performed by a licensed electrician.

    Unibräu 10G/20G/30G 240V option

    • 4 wire 120V power input
    • Nema 14-30 outlet (standard dryer receptacle) 
    • requires 30A breaker installed in the electrical panel
    • comes with our 5500W ultra low watt density brewing element 
    • 2m (6') power cord included from outlet to SV2 controller

    *A 30A GFCI breaker is recommended for extra protection.

    *Electrical installations should be performed by a licensed electrician.

    International 240V Option

    • 3 wire 240V input
    • Requires 30A breaker at electrical panel
    • bare stripped wire cord end supplied
    • comes with our 5500W ultra low watt density brewing element
    • 2m (6') power cord included from outlet to SV2 controller
    • 240V pump and controller pump outlet supplied 

     

    *Electrical installations should be performed by a licensed electrician.

    *A 30A GFCI breaker is recommended for extra protection.